Focal Rotor/Driver Ablation for Atrial Fibrillation: a Dream Come True?
Keywords:
atrial fibrillation, ablation, rotor ablationAbstract
The success of catheter ablation of atrial fibrillation (AF) remains modest despite the use of a variety of techniques, because the real target remains elusive. Even the endpoint of AF ablation is still under debate. It is not yet known whether isolation of the pulmonary veins (PVI), currently having a reproducible modest success rate when performed at the antrum and guided by electrophysiological mapping, is what is needed or additional foci should be routinely targeted. Some investigators have suggested that it is the ganglionated plexi (GPs) that mostly provide the triggers to the pulmonary veins, and GPs should be the primary targets during ablation. Others have focused on ablation of complex-fractionated atrial electrograms (CFAEs) claiming successful outcome; some have combined PVI with ablation of CFAEs. In cases of persistent AF, additional ablation lines and/or posterior atrial wall debulking have been applied to enhance the success rate of the procedure. Until recently, no focal ablation was ever reported to have any success in this patient population.
Recently, Narayan et al devised an optical computational approach and mapped localized electrical rotors and focal impulse sources in 49 patients with AF. Patients with persistent AF (n=30) had more sources than those with paroxysmal AF (2.1±1.0 vs 1.5±0.8, P=0.02), related to shorter cycle length (163±19 ms vs 187±25 ms, P<0.001). The majority of sources were found in the left atrium and only about a quarter of sources were localized in the right atrium. In a subsequent case report, the authors presented a patient with persistent AF who failed prior left atrial radiofrequency Maze and endocardial ablation procedures. Use of this novel computational mapping disclosed one AF rotor in the right atrium and another in the left atrium. Brief 3–5-minute ablation applications at each rotor terminated AF, which remained noninducible on testing, while no AF recurrence was reported over the next 6 months. In another study by the same group, the investigators localized rotors or focal sources (mean 2.1 sources) in 98 (97%) of 101 patients with sustained AF and then proceeded with ablation aiming at these targets. This novel approach with focal impulse and rotor modulation (FIRM) was applied in 36 patients and compared with conventional ablation performed in the other 71 patients... (excerpt)Downloads
Downloads
Published
Issue
Section
License
Authors who publish with this journal agree to the following terms:
a. Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
b. Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
c. Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).